The aim of the present study was to compare the results between percutaneous arteriovenous fistulas (p-AVFs) created with the Ellipsys device (Ellipsys Vascular Access System; Avenu Medical, San Juan Capistrano, Calif) and surgical arteriovenous fistulas (s-AVFs).
A single-center retrospective comparative study of the first 107 patients who had undergone p-AVF creation with the Ellipsys system from May 2017 to May 2018 with an equal number of consecutive patients who had undergone s-AVF creation in our center during the same period. The primary endpoints included the maturation and patency rates. The secondary endpoints were reintervention, risk of infection, and the incidence of steal syndrome and aneurysm formation.
The demographic, hypertension, and diabetes data were similar for both groups. The only difference between the two groups was that more p-AVF patients had already been receiving hemodialysis (61% vs 47%; P < .05). The p-AVFs showed superior maturation rates at 6 weeks (65% vs 50%; P = .01). The primary patency rates were greater for the s-AVFs at 12 months (86% vs 61%; P < .01).
Reference link- https://www.jvascsurg.org/article/S0741-5214(21)00137-3/fulltext