Effective traction is an important prerequisite for successful endoscopic submucosal dissection (ESD). The combined orthodontic rubber band (ORB) and clip method was effective in colorectal cancer ESD. To date, the method was not reported in gastric ESD. This study aimed to investigate its efficacy and safety for gastric neoplasms ESD.
We retrospectively analyzed data of 118 patients with gastric neoplasms treated by ESD from November 2020 to April 2022, 43 by ORB-ESD and 75 by the conventional ESD. The primary outcome measure was the ESD procedure time. Clinical data on efficacy and safety were also collected and analyzed. Propensity score matching (PSM) matched the patients in both groups.
PSM successfully matched 31 pairs of patients. The ORB-ESD operation time was shorter (median [interquartile range], 35 [30-48] vs. 49 [40-70] min, P < 0.001) and dissection speed was higher (median [interquartile range], 22.6 [14.4-29.3] vs. 13.5 [9.6-17.9] mm/min, P  0.05).
Compared to the conventional ESD, ORB-ESD significantly reduced the procedure time and increased the dissection speed, proving beneficial to gastric ESD.

© 2022. The Author(s).

Author