In a recent meta-analysis of randomized controlled trials, routine use of veno-arterial ECMO (VA-ECMO) did not improve outcomes in patients with acute myocardial infarction-related cardiogenic shock (AMI-CS), while a microaxial flow pump reduced mortality in a selected group of patients with AMI-CS in the DanGer-Shock trial.
Individual patient data of patients included in four randomized clinical trials investigating the routine use of VA-ECMO in AMI-CS were centrally analysed. For the purpose of this sub-analysis, DanGer-Shock-like patients were analysed (STEMI only, presumed low likelihood of brain injury). The primary endpoint was 180-day all-cause mortality. A total of 202 patients (106 randomized to VA-ECMO and 96 to control) were included. There were no differences in baseline characteristics, angiographic and interventional features between the two groups. Mortality after 6 months was numerically lower with VA-ECMO between the groups [45% in VA-ECMO group vs. 51% in control group; hazard ratio, 0.84; 95% confidence interval (CI), 0.56-1.26], while major bleeding (OR, 2.24; 95% CI, 1.08-4.64) and peripheral vascular complications (OR, 3.65; 95% CI, 1.15-11.56) were increased with the use of VA-ECMO.
In this exploratory subgroup analysis in patients with CS, STEMI, and a low likelihood of brain injury, there was no mortality benefit with the routine use of VA-ECMO. However, as indicated by the large confidence intervals, the statistical power was limited to draw definite conclusions.
© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.